Batt Charging Process Of charging SAFETY MEASURES meet before the charging Cover the (cover) for battery charging time can be opened between 20 ° -35 ° C in all cells that are dependent on electrolyte density 1280 g/cm3. This charge is deducted the value is reached. Electrolyte level in the battery for half an hour of rest has been set to maximum on the line by deleting the tool is attached. As charged or customer waiting in aqueous discharge from the charged battery to the data in the following table for the current and time are charged. May not be used, however, the intensity desired in the battery. The last two hours of battery chargers in the unchanged and the corrected charge density is sufficient. Fully closed in unopened Cover accumulator, according to the charging voltage is applied for. 1. Make sure the charger is not turned on. 2. Obtain the level of detection in the accumulator charged. 3. Connect the battery charger. Positive to positive-, negative-negative. Be careful not to do the reverse polarity connection. 4. According to the features and operating instructions for the charger current and voltage values that you want to select and connect the charger. 5. After charging the first charge before the split ends of the device off. 6. Extra charge to determine the requirements of the open circuit voltage is not required and the eyes of the measure density. Open Circuit Voltage Open Circuit Voltage = 11.70V-12.40V = <11.70VBattery Capacity (Ah) Charger A. And the same capacity at a time Charger sameı to more than one battery can be charged in parallel. Was lower in cold air discharge batteries will freeze in the (-5 ° C - -10 ° C) Do not try to charge a battery to freeze, at room temperature before charging to pay attention to.
Excessive charging of battery life shorting .27 ° C at the beginning of 1280 with the charge level of electrolyte Approximate Charging% open circuit V. Approximate Density 100 12.6V 1280 75 12.4V 1240 50 12.2V 1200 25 12.0V 1160
Note: Batteries for electronic systems that are disconnected will cause loss of memory, so this backup to prevent power from cigarette lighter plug connection can be made. Accumulators features and will be used to indicate the desired wear catologs call lists are correct according to the battery of choice. Measurements, flow and capacity for cold starters are the most important selection criteria. Dry the battery according to the above method and dilute if necessary with a pending charge edin.Water battery charger, the average daily temperature of less than 4C'of when open circuit voltage V, and under 12:50 in the above method according to the charge. Ambient temperature is high open circuit voltage falls below 12.40 volts and again the method according to the charge. New battery before removing the old battery to make proper connection cables + / - to be marked. By measuring the voltage value and the direction battery ensure the accuracy of the cable connections and battery tray, and carefully check to clear. Insert the new battery and insert and tighten connections. Positive (+) cable to connect first. Then the negative (-), connect the cable grounded. Tighten carefully. Excessive compression damage to the poles of the battery polarity is compressed be especially careful. Per pole and the cable ends to the plate with preservatives against rust. At the same time and same capacity to more than one battery can be charged in parallel.
|